GREENOx BT
MONOLITE JB
STELT
WALL M BOILERS
GREENOx BT
Main features:
The GREENOx BT COND is a three pass wet back boiler with condenser manufactured
with high quality steel to be fitted with burners for gaseous fuel operation.
Boiler is able to produce hot water with a maximum temperature of 110 °C.
Some of the product’s main features are related below:
– carbon steel boiler body.
– large volume combustion camber for single pass flame for low heat release,
three pass, wet back horizontal combustion chamber and supported by a completely
submerged nozzle.
– laser cut tube plate holes.
– EN10217-2 P235GH smoke ducts welded to tube plates, fitted with special helical
turbulators.
– third smoke pass made possible by double layer, tube in tube differential contact,
with anti-condensation feature.
– BAX condensing coil installed at the rear of the boiler, forming a single body
consisting in:
– AISI 316 Ti anti acid stainless steel, consisting of stainless steel plates with a particular
pressed formation in order to increase heat exchange surface area and
facilitate condensate droplet formation, allowing proper drainage.
– condensate collecting tray with inspection and cleaning door and lower part
drainage.
– boiler hydraulic connections
– boiler casing with flow and return flanged connections, working device connections,
inspection doors, all manufactured with approved welding procedures.
– embossed aluminum, round case cladding, high density glass wool, thick mattress
insulation.
– flat front door with reversible opening, inner high-insulating ceramic casing, pivoting
on hinges, easily opened by perforated rings equipped with levers as to
guarantee a perfect combustion gas seal and easy service.
– flat rear door, manufactured in high quality steel as to guarantee high heat resistance,
constructed in one piece that can be easily opened and that allows gas
duct inspections, fastened with bolts, equipped with chimney connection and
cleaning door.
Standard equipment:
– complete insulating casing
– turbolators
– cleaning brush
Ancillaries Code
Acid condensate Neutralizer system
Neutralizer 81020001
Neutralizer with pump 81020002
Control panels
Thermostatic control panel QACCBT01ELMCE
Features can be seen in “Thermostatic control panels section”
Boiler management
control panel QETERM01CE
Boiler management
control panel QETERM01RU2*
System management
control panel
QETERM02
For characteristics and other ancillaries see “ system” section
* This code refers to markets of: Russia, Belarus, Ukraine, Georgia
and Kazakhstan
Product CE marked according to the European
Directives in force:
92/42/CE – Efficiency (applicable up to 400 kW)
2009/142/CE – Gas
2014/30/UE – Electromagnetic Compatibility
2014/35/UE – Low Voltage
MONOLITE JB
Main features:
AISI 316 Ti stainless steel, single pass horizontal combustion chamber, vertical
heat exchanger, condensation MONOLITE JB Boiler is able to produce hot water
with a maximum temperature of 100 °C. Connectible to pressure air jet burner for
gas fuel operation.
Some of the product’s main features are related below:
– frame manufactured out of steel vertical profile structure, complete with floor
support.
– large cylindrical combustion chamber manufactured out of AISI 316 Ti stainless
steel, MIG pulse welded, able to withstand acid condensate attack.
– AISI 316 Ti anti acid stainless steel, vertical heat exchange surfaces, TIG welded,
grafted perpendicularly to the combustion chamber, consisting of stainless steel
plates printed with special conformity specifications in order to increase heat exchange
surface, and facilitate condensate droplet formation, allowing adequate
drainage. The heat exchange surface vertical arrangement also facilitates condensate
drainage, ensuring an effective plate self-cleaning function.
– welding carried out with TIG method, method which does not require weld material,
and therefore guarantees stainless steel main mechanical characteristics,
without sacrificing corrosion resistance to acid condensation.
– flanged flow connection and two system return connections for boiler differential
temperature input and ensure minimum possible temperature in lowest
point of the condensation curve and then take maximum advantage from the
condensation process even in the presence of medium-high temperature returns.
– exhaust gas chamber able to collect resultant condensate and discharge it
through a water trap connected to a neutralizer (where provided) to the domestic
water drainage system.
– high water content and low thermal load.
– heat dispersion surface insulation with thick glass wool mattress, protected with
steel varnished panels that can be easily removed
– front door with reversible steel sheet opening thermally insulated with ceramic
fiber.
Standard equipment:
– complete insulating casing
Ancillaries Code
Acid condensate Neutralizer system
Neutralizer 81020001
Neutralizer with pump 81020002
Control panels
Thermostatic control panel QCOND01ELMCE
Features can be seen in “Thermostatic control panels section”
Boiler management
control panel QETERM01CE
Boiler management
control panel QETERM01RU2*
System management
control panel
QETERM02
For characteristics and other ancillaries see “ system” section
* This code refers to markets of: Russia, Belarus, Ukraine, Georgia
and Kazakhstan
Product CE marked according to the European
Directives in force:
92/42/CE – Efficiency (applicable up to 400 kW)
2009/142/CE – Gas
2014/30/UE – Electromagnetic Compatibility
2014/35/UE – Low Voltage
STELT
Main features:
STELT condensing boiler, made from AISI 316 Ti stainless steel with reverse flame
combustion chamber able to produce hot water at a maximum temperature of
110 °C. Connected to pressure jet burners operating on gaseous fuels.
Some of the product’s main features are related below:
– inclined boiler body for condensate drainage support
– large cylindrical combustion chamber with reversed flame manufactured from
AISI 316 Ti stainless steel, TIG pulse welded, able to withstand acid condensate
attack.
– stainless steel gas passages with special profiles, placed around the combustion
chamber in order to extend flue gas development and consequently increase
heat exchange and increase boiler efficiency (obtaining low NOx emissions in
conjunction with Low NOx burners)
– heat exchange surfaces made from AISI 316 Ti stainless steel, welded with TIG
method, consisting of stainless plates characterized by a particular corrugated
shape being able to increase heat exchange surface, and facilitate droplet condensate
formation allowing adequate drainage.
– welded using TIG, MIG and plasma procedures, methods that guarantee stainless
steel main mechanical characteristics, without sacrificing corrosion resistance to
acid condensation.
– flanged flow connection and two system return connections for boiler differential
input and ensuring minimum possible temperature to take advantage of
condensing benefits even in case of medium-high temperature returns.
– flue gas chamber able to collect resultant condensate and discharge it through a
water trap connected to a neutralizer (where provided) to the waste water drainage
system.
– burner mounting plate, for attaching pressure jet burners for gaseous fuels use.
– heat dispersion surface insulation with thick glass wool mattress, protected with
steel varnished panels that can be easily removed
– front door with reversible steel sheet opening thermally insulated with ceramic
fiber.
Standard equipment:
– complete insulating casing
Ancillaries Code
Acid condensate Neutralizer system
Neutralizer 81020001
Neutralizer with pump 81020002
Control panels
Thermostatic control panel QCOND01ELMCE
Features can be seen in “Thermostatic control panels section”
Boiler management
control panel QETERM01CE
Boiler management
control panel QETERM01RU2*
System management
control panel
QETERM02
For characteristics and other ancillaries see “ system” section
* This code refers to markets of: Russia, Belarus, Ukraine, Georgia
and Kazakhstan
Product CE marked according to the European
Directives in force:
92/42/CE – Efficiency (applicable up to 400 kW)
2009/142/CE – Gas
2014/30/UE – Electromagnetic Compatibility
2014/35/UE – Low Voltage
WALL M BOILERS
Main features:
WALL condensing boiler, with both European and Italian Patent designed by ICI
Caldaie for high power in contained spaces.
Particular boiler geometry together with large heat exchange surfaces allow considerable
flue gas temperature reduction resulting in 109% efficiency achievement
(referring to PCI and Temp. Delivery/Return 50/30 °C). Latest concept burner,
20% to 100% Nominal Power pre-mix flame modulation. Reduced environmental
impact achieved by under 10 ppm NOx emissions.
Some of the product’s main features are related below:
– large Combustion Chamber, single pass flame with dry and low thermal load
reversal chamber
– crossed groove, W stainless steel, high efficiency flue gas duct
– reverse double slope structure for condensate integral recovery, high and low
temperature double return.
– parts in contact with combustion products – combustion chamber and gas
plates – are entirely made out of AISI 316 Ti titanium stabilized stainless steel.
– cascade operation in advance setup with 125 kW and 150 kW modules having
a maximum of 4 boilers, reaching a maximum power of 600 kW reached using
condensing operation.
– modulating gas burners with total gas pre-mix, heat radiating cylindrical body,
low NOx emission (below 10 ppm)
– 20 to 100% maximum power adjustment.
– 109% COP (coefficient of performance), 50/30°C boiler water temperature
– each module is equipped with a digital control panel for burner modulation
management and climatic compensation for fluctuating temperature.
– AISI 316 L STAINLESS STEEL external casing, internally insulated with high density,
thick mineral wool mattress.
– IPX4D protection
Ancillaries Code
Acid condensate Neutralizer system
Neutralizer 81020001
Neutralizer with pump 81020002
System management control panel QETERM02
For characteristics and other ancillaries see “ system” section
WALL model to be assemled
WALL M model supplied assembled on its base
Standard equipment:
– flow Manifold, high-low temperature dual return
– INAIL security devices
– combustion gas collector
– gas collector
– cascade climatic regulator
– operational with methane and GPL
– flow Manifold probe (in presence of 2 or more
modules)
– control panel equipped with:
– main switch
– manual or Automatic burner operation switch
– control thermostat
– safety thermostat
– thermometer
– microprocessor board
– boiler probe
– external probe (only for master control panel)
– GSM modem
Product CE marked according to the European
Directives in force:
92/42/CE – Efficiency (applicable up to 400 kW)
2009/142/CE – Gas
2014/30/UE – Electromagnetic Compatibility
2014/35/UE – Low Voltage